Views: 0 Author: Sunny Zhang Publish Time: 2026-11-11 Origin: Site
When planning a tube ice production project, choosing between an integrated tube ice machine and a split-type tube ice machine is an important decision. Both types can produce tube ice for food processing, seafood preservation, beverages and industrial cooling. However, they differ in equipment structure, installation requirements, refrigeration system design and future expansion options.
The right choice depends on your daily ice production demand, available space, local operating conditions and future business plans. Understanding these differences can help you select a tube ice machine that fits your project.
An integrated tube ice machine combines the main refrigeration components, evaporator, control cabinet and connecting pipes into one compact unit. This design is suitable for small and medium-sized ice production projects where space, transportation and installation are important considerations.
Compact Structure and Smaller Footprint:
The main components are built into one unit, reducing the space needed for installation. This makes integrated tube ice machines suitable for edible ice plants, beverage ice suppliers and businesses with limited installation space.
Better Use of Container Space
The compact design allows the machine to be packed and shipped as a complete unit. Compared with separate refrigeration and ice-making equipment, this arrangement can help make better use of container space and simplify shipping.
Factory-Installed Refrigeration Piping
The refrigerant pipes are installed and tested at the factory before shipment. This means no refrigerant pipe welding is required at the customer's site, reducing on-site installation work.
Water pipes and electrical connections are also prepared according to the machine configuration. After delivery, customers mainly need to connect the water and power supplies and complete the required installation checks and commissioning before starting production.
For overseas buyers, this arrangement can make installation easier and reduce the need for local refrigeration pipe installation work.
Integrated tube ice machines are commonly used in small and medium-sized edible ice plants, local ice distribution businesses and beverage ice supply projects.
A split-type tube ice machine has separate evaporator units and a main refrigeration system. This design provides more flexibility in equipment layout and refrigeration system configuration.
Split-type tube ice machines are particularly suitable for large ice production projects with daily capacities of 30 tons or more, including projects using ammonia refrigeration.
Suitable for Large Production Capacity
The separate evaporators and refrigeration equipment allow the system to be designed for large-scale ice production. Equipment layout can be planned according to available space, production demand and cooling conditions.
Suitable for Ammonia Refrigeration Systems
For large industrial ice plants, ammonia (NH₃) can be used as the refrigerant when the system is designed for ammonia refrigeration. This option is suitable for projects requiring high ice production capacity and a centralized refrigeration system.
Ammonia refrigeration systems require suitable equipment, piping and safety controls, along with professional system design and installation.
Multiple Evaporators Sharing One Refrigeration System
Multiple tube ice evaporators can be connected to one main refrigeration system. Instead of using a separate refrigeration unit for each evaporator, a centralized system can supply refrigeration to several ice-making units.
This arrangement provides more flexibility in equipment configuration and production planning.
Load Control for Better Part-Load Efficiency
The main refrigeration system can adjust its operating capacity according to actual ice production demand. When fewer evaporators are running, the refrigeration output can be adjusted to match the current load.
With proper compressor capacity control and system design, a shared refrigeration system can operate more efficiently under partial-load conditions. Actual energy performance depends on the equipment configuration and operating conditions.
Flexible Capacity Expansion
When ice production demand increases, additional evaporators can be added to the existing refrigeration system. This means the entire system may not need to be replaced when expanding production.
However, the existing compressor unit, condenser, pumps, piping and control system must have enough spare capacity to handle the additional load. If the existing system cannot support the new evaporators, some components may need to be upgraded.
This design gives large ice plants more flexibility when planning future production expansion.
Comparison |
Integrated Type |
Split Type |
|---|---|---|
Equipment structure |
Compact integrated unit |
Separate units |
Floor space |
Smaller footprint |
Flexible layout |
Container loading |
Compact overall packing |
Depends on equipment layout |
Refrigerant piping |
Factory-installed and tested |
Installed according to system design |
On-site installation |
Connect water and power, then complete checks |
Requires professional refrigeration connections |
Typical daily capacity |
2–30 tons |
30 tons and above |
Refrigeration system |
Integrated refrigeration unit |
Centralized refrigeration system |
Refrigerant options |
Depends on machine configuration |
Can use ammonia refrigeration |
Multiple evaporators |
Depends on machine model |
Can share one refrigeration system |
Load control |
Depends on machine configuration |
Centralized load control |
Future expansion |
Depends on the capacity of the integrated unit |
Additional evaporators can be added if system capacity allows |
Before choosing an integrated or split-type tube ice machine, consider the following factors.
Daily Ice Production Demand
First, determine how much tube ice you need to produce each day. Integrated machines are suitable for many projects with daily capacities of 2–30 tons, while split-type systems are generally used for larger projects with daily capacities of 30 tons or more.
Installation Space and Transportation
If your installation space is limited or container shipping costs are an important consideration, an integrated machine may be a suitable choice. For large projects with separate equipment areas, a split-type system provides more flexibility in equipment layout.
Local Operating Conditions
Ambient temperature, cooling water temperature, ventilation and heat rejection capacity all affect refrigeration performance. The refrigeration system should be selected according to the actual operating conditions at the installation site.
Installation and Maintenance Resources
Factory-installed refrigeration piping can simplify installation for overseas projects. Large split-type systems, especially ammonia refrigeration systems, require professional installation and maintenance support.
Future Expansion Plans
If you expect ice production demand to increase, consider whether the refrigeration system can support additional evaporators. Before expansion, the available capacity of the compressor unit, condenser, pumps, piping and control system should be checked.
As a tube ice machine manufacturer in China, ICEMEDAL provides integrated and split-type tube ice machines for different production capacities and industrial applications.
Our equipment configurations can be planned according to daily ice production demand, tube ice size, installation space, ambient temperature and refrigeration requirements.
With in-house manufacturing, factory assembly and equipment testing, ICEMEDAL provides equipment selection support, installation guidance and technical assistance for customers.
Whether you are planning a small edible ice plant or a large industrial ice production facility, choosing the right machine structure is an important step in planning your tube ice production system.
Contact ICEMEDAL to discuss your required daily production capacity, tube ice size and installation conditions. Our team can help you find a suitable tube ice machine configuration for your project.